Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex Indirect Oil-Fired Heater at the bottom of a hill nearby to a reservoir with ducting going up the hill supplying heat to the project
Climex Indirect Oil-Fired Heater from the side with a splitter attached and two lines of ducting going into the bottom floor and second floor of a live new build project
Climex Indirect Oil-Fired Heater outside a cathedral, provindg warm air inside whilst maintenance is carried out inside
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex-Indirect-Oil-Fired-Heater
Climex Indirect Oil-Fired Heater at the bottom of a hill nearby to a reservoir with ducting going up the hill supplying heat to the project
Climex Indirect Oil-Fired Heater from the side with a splitter attached and two lines of ducting going into the bottom floor and second floor of a live new build project
Climex Indirect Oil-Fired Heater outside a cathedral, provindg warm air inside whilst maintenance is carried out inside
Indirect Oil-Fired Heaters
Climate Control

CLIMEX® Indirect Oil Fired Site Heaters

65kW-110kW-150kW-200kW industrial-sized Mobile Heaters

These efficient climate control solutions (65kW – 200kW) work by constantly heating large volumes of fresh air and displacing damp air in a new build or project.

CLIMEX®-indirect-oil-fired-site-heater-with-ducting-going-into-a-building-with-ducting-split-off-into-multiple-ducting-points
Indirect Oil Fired Heaters

Key Features and Applications

Each CLIMEX® Indirect Oil Fired Site Heater has wheels for full mobility, making it easy to get into place on your project and move around as required.

Add To Quote
Product Comparison

Comparison Table for CLIMEX® Indirect Oil Fired Site Heater

Climex Indirect Oil-Fired Heater
Climex Indirect Oil-Fired Heater
Climex Indirect Oil-Fired Heater
Climex Indirect Oil-Fired Heater
65kW Heater
Heat Output 65kW 
Heat Output (BTU) 221,780 
Airflow 4,000m³/h 
Maximum Fuel Consumption 6.5L per hour 
Heater Fuel Line 3/8" male connector 
Ducting Diameter 450mm 
Plug 32a 3-pin 
Voltage 110v 
Running Current 15 amps 
Remote Thermostat Optional Extra 
Max. recommended extension lead run 20m 
Minimum Power Supply ‘D’ rated circuit breaker 
(10kva continuous transformer recommended) 
Noise Level 75.5 dba 
(Noise levels are given as a guidance only, as the location and loading of the heater will affect the final noise output.) 
Length 1,990mm 
Width 710mm 
Height 1,280mm 
Weight 245kg 
Download Spec Sheet
110kW Heater
Heat Output 110kW 
Heat Output (BTU) 375,320 
Airflow 8,000m³/h 
Maximum Fuel Consumption 10.9L per hour 
Heater Fuel Line 3/8" male connector 
Ducting Diameter 500mm 
Plug 32a 3-pin 
Voltage 110v 
Running Current 32 amps 
Remote Thermostat Optional Extra 
Max. recommended extension lead run 42m 
Minimum Power Supply ‘D’ rated circuit breaker 
(10kva continuous transformer recommended) 
Noise Level 81.5 dba 
(Noise levels are given as a guidance only, as the location and loading of the heater will affect the final noise output.) 
Length 2,230mm 
Width 780mm 
Height 1,342mm 
Weight 350kg 
Download Spec Sheet
150kW Heater
Heat Output 150kW 
Heat Output (BTU) 518,624 
Airflow 9,000m³/h 
Maximum Fuel Consumption 14.8L per hour 
Heater Fuel Line 3/8" male connector 
Ducting Diameter 500 or 600mm 
Plug 32a 3-pin 
Voltage 110v 
Running Current 32 amps 
Remote Thermostat Optional Extra 
Max. recommended extension lead run 42m 
Minimum Power Supply ‘D’ rated circuit breaker 
(10kva continuous transformer recommended) 
Noise Level 81.5 dba 
(Noise levels are given as a guidance only, as the location and loading of the heater will affect the final noise output.) 
Length 2,460mm 
Width 840mm 
Height 1,510mm 
Weight 385kg 
Download Spec Sheet
200kW Heater
Heat Output 200kW 
Heat Output (BTU) 682,000 
Airflow 13,000m³/h 
Maximum Fuel Consumption 19.4L per hour 
Heater Fuel Line 3/8" male connector 
Ducting Diameter 600mm 
Plug 32a 3-pin 
Voltage 415v 
Running Current 10 amps 
Remote Thermostat Optional Extra 
Max. recommended extension lead run 20m 
Minimum Power Supply ‘D’ rated circuit breaker 
(10kva continuous transformer recommended) 
Noise Level 82.5 dba 
(Noise levels are given as a guidance only, as the location and loading of the heater will affect the final noise output.) 
Length 2,710mm 
Width 910mm 
Height 1,520mm 
Weight 450kg 
Download Spec Sheet
Next steps

Choosing the Right Solution

  • Step One: Discuss

    Contact us in a way that works best for you. Whether you email, telephone or complete an online enquiry form, a member of the team will be ready to help.
  • Step Two: Plan

    Once we know what the challenge is, we'll contact you and recommend an effective hazard control solution that protects your people and keeps your project on track.
  • Step Three: Execute

    When you're ready to place an order, we'll ask you to organise a PO, and we'll take care of the rest. Our service includes providing the RAMS and logistics for any solutions that you have on site. Once delivered, you can rest assured with ongoing technical support, engineer access and superior customer service throughout the hire.
Send an Enquiry to RVT Group

Technical Enquiries & Pricing

Please provide your project requirements in the form provided to receive a quotation or detailed technical specifications. Our specialist team will assess your site's needs to ensure this equipment provides the most effective hazard control solution.

Dartford-Office-People-On-the-Phone

Product Specification & Quotation Request

Interested in this solution for your project? Submit the form below to obtain a no-obligation quote or further technical information. An RVT Group specialist will review your enquiry and respond promptly with the details you require.

Indirect Oil Fired Heaters

Related Resources

TESTIMONIALS

Client Experiences that Speak for Themselves

“My thanks go out to the RVT team. You played a massive role by providing the air volume and temperature analysis, as well as the most cost-effective solution that ensured we had perfect conditions suitable for screeding, rendering, waterproofing and tiling. This meant time wasn't lost on the programme and high quality was maintained.”

light-asset icon

Wates